Who can edit: Superuser Admin Field Tech · Viewer sees a read-only sheet · Where: select any asset, or scan the asset's QR sticker
An asset's page is the complete record for one piece of electrical equipment. It is also where a QR sticker scan lands, so it shows each role what that role needs.
Scanning a QR sticker
Each asset's QR code links to this page by its tag number. Scanning always asks you to sign in first.
- Admins and Field Techs see the full page with every editing tool.
- Viewers see a clean read-only sheet: no editing, no QR card, and none of your internal or draft deficiency notes. That makes Viewer accounts safe to give to your client's staff; they can scan an asset on their own floor and see its status without seeing your internal notes.
Header buttons
- Edit (Full Page): the complete edit form. You return here when you save.
- Quick Edit: a box for the fields you change most often (tag number, name, site, location, make and model, NEMA and voltage, and the condition fields) without leaving the page. Field techs can't change the site here; moving an asset to another site is an admin task.
- Audit History: slides out a log of every change to this asset (what changed, when and by whom). Print All prints the whole log.
- Print Report: opens the asset's report in a new tab, ready to print or save.
- Create Snapshot: records an inspection snapshot (see below).
- Add New Asset: starts a new asset at the same site.
- Delete Asset (admins) or Request Delete (field techs): see Delete an asset.
The Managed / Unmanaged switch is admin-only. Field techs and viewers see the status but can't change it.
Attribute values
Every detail recorded for the asset, grouped as your tenant has arranged them for this asset type. A Fed by value links straight to the asset that feeds this one.
Deficiency status
Shows the asset's current deficiency, if any: type, priority (Low, Medium or High), status (Open, In Progress or Resolved) and notes, with an orange Deficiency badge while one is open. The section also shows the two condition ratings:
- Recommended Physical Condition of Electrical Equipment: Condition 1, 2 or 3.
- Recommended Condition of Maintenance (NFPA 70B): Serviceable, Limited Service or Nonserviceable.
Use Log New Deficiency to record a new one with photos. Each deficiency keeps its own history, and the page always shows the most recent unresolved one as the current state. Notes come in three kinds:
| Notes | Who sees them |
|---|---|
| Internal Notes | Your team only, never Viewers or reports |
| Customer-Facing Notes (Draft) | Your team only, while you are writing them |
| Customer-Facing Notes (Final) | Printed on reports and visible to Viewers |
Photos and files
Image and file attributes (asset photos, IR images, IR reports, digital IDs) show as thumbnails; select one to see it full size, and use the rotate buttons to fix a sideways photo. IR reports keep every PDF uploaded, newest first, so the thermal history builds up instead of being replaced.
Removing a file doesn't destroy it. It goes to the dashboard's Removed files: pending review queue, where an admin confirms the removal or restores the file.
Components
When an asset has parts that are tracked as their own assets (for example, the inverters and strings of a solar system), they are listed here. Select one to open it. The card only appears when there are components.
Notes Timeline
A dated log of notes about the asset, visible to everyone who can see the asset. Field techs and admins can add and edit notes; each edit is kept, and Note Revision History shows earlier versions.
Asset QR
Shows the asset's QR code with Download PNG for printing a sticker. The code is based on the tag number, so it keeps working when other details change and matches stickers pre-printed from the same tag number.
Inspection snapshots
Create Snapshot saves the asset's details as they are right now, with optional notes, to mark "as inspected on this date". Last Inspection Snapshot shows the most recent one, and Inspection History lists them all with who took each and when.
Delete an asset
Delete Asset shows what will be removed with the asset (its values, photos and files) and asks you to confirm. Field techs see Request Delete instead, which sends the request to an admin.
A deleted asset can be restored from Delete Requests for your tenant's restore window (30 days unless changed). Its tag number stays reserved. If an asset is simply out of service, retire it from Manage assets instead of deleting it.
Troubleshooting
- Scanning a QR code opens a sign-in page.
- That is expected; every scan needs an account. Your client's staff need a Viewer account for their client.
- A Viewer can't see the deficiency notes.
- Viewers only see final customer-facing notes. Move what they should see into Customer-Facing Notes (Final).
- The Site field in Quick Edit is locked.
- You're signed in as a field tech. Ask an admin to move the asset.
- I removed the wrong file.
- Ask an admin to restore it from Removed files: pending review on the dashboard.
- The page says the asset was deleted.
- It shows who deleted it, when, and the date it can be restored until. An admin can restore it from that page or from Delete Requests.
Related articles
- Manage assets
- Site details
- Tags
- Manage users — Viewer accounts for your clients
Last updated Oct 4, 2026